KOROK Apartment Wall Solutions

KOROK Apartment Wall Solutions

KOROK Apartment Wall Solutions

The Ultimate All-in-One Solution for Fire & Acoustic Rated Intertenancy Wall Systems

For over  25 years, KOROK has been a trusted provider of high-performance fire and acoustic walls for the multi-level construction market. Now, with the introduction of the KOROK KIR high-performance intertenancy apartment wall systems, KOROK offers comprehensive solutions for seamless floor plate transitions.

Our systems integrate lift cores, riser ducts, stair cores, hallways, and apartments into one streamlined package. Experience unparalleled fire, seismic, acoustic, and safety protection with KOROK – your all-in-one solution for modern construction needs.

Simplify with KOROK: Combining Performance and Safety

Experience the perfect blend of simplicity and performance with KOROK. Our range of IT wall solutions incorporates fire protection, seismic deflection, passive safety, and acoustic efficiency, all while eliminating complex build-ups. KOROK delivers unmatched performance, safety, and simplicity for your construction needs.

Intertenancy Apartment Solution

  • Early Installation
  • Solid & Secure
  • Tested performance
  • STC rating from 55 up to 69
  • Fire rating from FRR 30 to FRR 120
  • Simplified program continuity
  • Waste reduction with custom lengths

Read More

KOROK Apartment Wall Solutions

Wall Transition

  • Tested Fire Door Solutions
  • Simple transitioning for interface junctions

Corridor, Service Riser & Ducts

  • Multiple wall design solutions
  • Single-sided fix
  • Non-weather dependent
  • Simple passive fire service penetrations allowing for early services installation
  • Programme Continuity
  • Reduction in scaffolding
  • Early Inspection & installation

Lift Cores

  • Structural steel infills
  • Intumescent coated steel connections
  • Slab to Slab options
  • Early fix services & lift components
  • Added fall protection
  • Simple penetration solutions
  • Door head solutions
  • Early installation & sequencing continuity

Read More

Lift Shafts, Risers, Ducts Fire and Acoustic Rated Protection

Stair Core & Scissors Stairs

  • Safe exit
  • Linings are optional
  • Prefinished colour coated panel options
  • Prefinished panel provide a cost-effective, single fixed solution
  • Reduced structural steel
  • Multiple installation solutions
  • Programme continuity
  • Small crew to install
  • Lightweight simplicity
  • Handrail connection

Read More

KOROK Scissor Stairs

Recent Articles

Stay in the loop

Sign-up to our newsletter to be notified of updates.

Read more

Systems

Systems

.vc_custom_1419253765784{background-color: rgba(0,0,0,0.3) !important;*background-color: rgb(0,0,0) !important;}
Read more
Passive Fire Penetrations

Passive Fire Penetrations

KOROK® Passive Fire Penetrations

When it comes to passive fire penetrations, KOROK® leads the way with innovative solutions that ensure fire safety without compromising functionality.

At KOROK®, we are committed to providing fire-rated wall systems that prioritize safety, durability, and performance. Our advanced KOROK® panels are specifically designed to allow seamless integration of passive fire penetrations, including service ducting and pipes, while maintaining the structural and fire integrity of the wall.

What Are Passive Fire Penetrations?

Passive fire penetrations are openings or pathways in fire-rated walls or floors that allow services such as plumbing, electrical cables, or ductwork to pass through. These penetrations are essential for building functionality but must be carefully designed to prevent the spread of fire and smoke. KOROK® panels are engineered to make the creation and sealing of these penetrations straightforward and effective, ensuring compliance with strict fire safety standards.

Why Choose KOROK® for Passive Fire Penetrations?

  • Easy Formations for Penetrations: KOROK® panels simplify the creation of openings for ducting and plumbing. The lightweight yet robust design makes it easy to form precise and efficient penetrations without compromising fire safety or wall integrity.
  • Maintained Wall Integrity: Even with multiple passive fire penetrations, KOROK® panels ensure the overall wall system retains its fire rating. This is crucial for preventing fire and smoke from spreading across compartments in a building.
  • Versatile Applications: Whether your project involves commercial spaces, residential apartments, or industrial facilities, KOROK® passive fire penetrations provide a reliable and efficient solution tailored to meet your needs.
  • Compliance with Building Codes: KOROK® panels are rigorously tested and meet or exceed New Zealand’s building code requirements for passive fire protection. This gives architects, engineers, and builders confidence in the safety and performance of their projects.

The table below contains a basic selection of tested passive fire solutions, for quick reference. For additional solutions please contact the relevant passive fire companies:

Service Penetrations – KOROK® 51mm & 78mm Panel

MANUFACTURERPENETRATION DESCRIPTIONSIZESUBTYPESYSTEMFRR51MM PANEL DRAWING78MM PANEL DRAWING
Promat¼” & ½” PE insulated pair coil and power cableCableFCW50-/90/60<a
<a
Promat1 of 2.5 mm² TPS cable2.5mmCablePromaseal A Sealant-/90/60<a
<a
Promat100 mm PE pipe100mmPE / PEXFCW100-/90/60<a
<a
Promat100 mm uPVC pipe100mmuPVCFCW100-/90/60<a
<a

Promat19 mm copper pipe with 13 mm Armaflex insulation19mmCopper pipeFlexiwrap-/90/30
Promat20 mm PEX20mmPE / PEXCFC32-/90/60<a
<a
Promat40 mm PE pipe40mmPE / PEXFCW40-/90/60<a

<a

Promat40 mm uPVC pipe40mmuPVCFCW40-/90/60<a
<a
Promat50 mm copper pipe50mmCopper pipeSupawrap 40-/90/60<a
<a
Promat50 mm uPVC pipe50mmuPVCFCW50-/90/60<a

<a

PromatUp to 3 of CAT6 data cablesCablePromaseal A Sealant-/90/60<a

<a

PromatUp to 4 of 2.5 mm² TPS cablesCablePromaseal A Sealant-/90/60<a

<a
PromatUp to 4 x 2.5 mm² TPS cable in a 30 mm flexible uPVC conduituPVC, CableDouble CFC32-/90/60<a
<a
PromatUp to 800mm x 400mm (0.32m²) openingOpeningPromat double bulkhead-/90/60<a
<a
PromatUp to 800mm x 400mm (0.32m²) opening with continuous cable trayCablePromat double bulkhead-/90/60<a
<a
Ryanfire150 mm uPVC pipe150mmuPVC2 of Ryanfire SL160 collars-/90/60
Ryanfire50 mm uPVC pipe50mmuPVC2 of Ryanfire SL55 collars-/90/60
RyanfireA combination of up to 3 of 3/8” & 3/4” PE insulated pair coil + 6 of 2.5 mm² TPS cables + 25mm diameter uPVC conduituPVC, Cable2 of Ryanfire SL110 collars-/90/30
RyanfireA combination of up to 30 of 2.5mm² TPS cables + 25 of CAT6 cables + 10 of 50pr telecommunications cablesCable2 of Ryanfire SL110 collars-/90/60
RyanfireUp to 700mm x 400mm (0.28m²) openingOpeningRyanfire double Firetherm Intubatt-/90/60
Holyoake
Holyoake
Hilti1 of Multi-Core Copper Cables PVC/PVC & XLPE/PVC (sheath/insulation) circular or flat 2C+E or 3C+E up to 25mm2 ≤ 23mm Dia. Refer to page 11Max. 23mmCableCP611a / CFS-IS Intumescent Sealant-/120/60
Hilti1 of Multi-Core Copper Cables PVC/PVC & XLPE/PVC (sheath/insulation) circular or flat 2C+E or 3C+E up to 25mm2 ≤ 23mm Dia. Refer to page 12Max. 23mmCableCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch-/120/90
Hilti1 of single core copper cable PVC/PVC & XLPE/PVC (sheath/insulation) circular cables up to 25mm2 ≤ 10mm Dia. Refer to page 11Max. 10mmCableCP611a / CFS-IS Intumescent Sealant-/120/90
Hilti1 of single core copper cable PVC/PVC & XLPE/PVC (sheath/insulation) circular cables up to 25mm2 ≤ 10mm Dia. Refer to page 12Max. 10mmCableCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch-/120/120
Hilti1 of Telecommunication cables, Cat5/6/7/8, RG6 Coax Cables & Fiber Optic cables. Refer to page 11CableCP611a / CFS-IS Intumescent Sealant-/120/90
Hilti1 of Telecommunication cables, Cat5/6/7/8, RG6 Coax Cables & Fiber Optic cables. Refer to page 12CableCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch-/120/120
Hilti110mm ND uPVC-SC Pipe . Refer to pages 28-30110mmuPVCCFS-C P 110/4" Fire Collar+ CP606 Acrylic Sealant-/120/60
Hilti110mm ND uPVC-SC Pipe . Refer to pages 28-30110mmuPVCCFS-C P 110/4" Fire Collar+ CP606 Acrylic Sealant + 13mm Plasterboard Patch-/120/90
Hilti150mm ND uPVC-SC Pipe . Refer to pages 28-30150mmuPVCCFS-C P 160/6" Fire Collar+ CP606 Acrylic Sealant-/120/60
Hilti150mm ND uPVC-SC Pipe . Refer to pages 28-30150mmuPVCCFS-C P 160/6" Fire Collar+ CP606 Acrylic Sealant + 13mm Plasterboard Patch-/120/90
Hilti16 - 200mm Dia. Copper, Ferrous (Steel, Stainless Steel, Iron) or Brass Pipe with Mineral Stone Wool Insulation. Refer to pages 34-37Max. 200mmBattsCP606 Acrylic Sealant + 1 x 13mm Plasterboard Patch + Mineral Wool Pipe Sleeve (Fibertex 450) 600mm in length-/120/30
Hilti16 - 200mm Dia. Copper, Ferrous (Steel, Stainless Steel, Iron) or Brass Pipe with Mineral Stone Wool Insulation. Refer to pages 34-37Max. 200mmBattsCP606 Acrylic Sealant + 1 x 13mm Plasterboard Patch + Mineral Wool Pipe Sleeve (Fibertex 450) 600mm in length-/120/60
Hilti16 - 200mm Dia. Copper, Ferrous (Steel, Stainless Steel, Iron) or Brass Pipe with Mineral Stone Wool Insulation. Refer to pages 34-37Max. 200mmBattsCP606 Acrylic Sealant + 1 x 13mm Plasterboard Patch + Mineral Wool Pipe Sleeve (Fibertex 450) 600mm in length-/120/90
Hilti16 - 200mm Dia. Copper, Ferrous (Steel, Stainless Steel, Iron) or Brass Pipe. Refer to pages 34-37Max. 200mmSealantCP606 Acrylic Sealant-/120/-
Hilti16 to 32mm Dia. uPVC Rigid conduit filled with Cables, Fiber Optics or mixture of both. Refer to pages 15-17Max. 32mmuPVC, CableCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch-/120/90
Hilti16 to 50mm Dia. uPVC Rigid conduit (Empty). Refer to pages 15-16Max. 50mmuPVCCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant-/120/60
Hilti16 to 50mm Dia. uPVC Rigid conduit (Empty). Refer to pages 15-17Max. 50mmuPVCCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch-/120/90
Hilti16 to 50mm Dia. uPVC Rigid conduit filled with Cables, Fiber Optics or mixture of both. Refer to pages 15-16Max. 50mmuPVC, CableCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant-/120/60
Hilti16mm Dia. PE-X/AL/PE or PE-Xb/AL/PE-Xb. Refer to pages 31-3316mmPE / PEXCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch & Sealant Cone-/120/90
Hilti16mm Dia. PE-X/AL/PE. Refer to pages 31-3216mmPE / PEXCP611a / CFS-IS Intumescent Sealant-/120/60
Hilti16mm Dia. PE-Xa or PE-Xb. Refer to pages 31-3316mmPE / PEXCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch & Sealant Cone-/120/120
Hilti16mm Dia. PE-Xa. Refer to pages 31-3216mmPE / PEXCP611a / CFS-IS Intumescent Sealant-/120/90
Hilti20 & 25mm Dia. PP Flexible conduit (Empty). Refer to pages 18-19Max. 25mmCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant-/120/-
Hilti20 & 25mm Dia. PP Flexible conduit filled with Cables, Fiber Optics or mixture of both. Refer to pages 18-19Max. 25mmCableCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant-/120/60
Hilti20 & 25mm Dia. PP Flexible conduit filled with Cables, Fiber Optics or mixture of both. Refer to pages 18-20Max. 25mmCableCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch-/120/90
Hilti20 to 50mm Dia. uPVC Flexible conduit (Empty). Refer to pages 18-19Max. 50mmuPVCCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant-/120/-
Hilti20 to 50mm Dia. uPVC Flexible conduit filled with Cables, Fiber Optics or mixture of both. Refer to pages 18-19Max. 50mmuPVC, CableCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant-/120/90
Hilti20 to 50mm Dia. uPVC Flexible conduit filled with Cables, Fiber Optics or mixture of both. Refer to pages 18-20Max. 50mmuPVC, CableCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + CP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch-/120/120
Hilti20mm Dia. PE-X/AL/PE or PE-Xb/AL/PE-Xb. Refer to pages 31-3320mmCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch & Sealant Cone-/120/90
Hilti20mm Dia. PE-X/AL/PE. Refer to pages 31-3220mmCP611a / CFS-IS Intumescent Sealant-/120/60
Hilti20mm Dia. PE-Xa or PE-Xb. Refer to pages 31-3320mmCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch & Sealant Cone-/120/120
Hilti20mm Dia. PE-Xa. Refer to pages 31-3220mmCP611a / CFS-IS Intumescent Sealant-/120/90
Hilti25mm Dia. PE-X/AL/PE or PE-Xb/AL/PE-Xb. Refer to pages 31-3325mmCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch & Sealant Cone-/120/90
Hilti25mm Dia. PE-X/AL/PE. Refer to pages 31-3225mmCP611a / CFS-IS Intumescent Sealant-/120/60
Hilti25mm Dia. PE-Xa or PE-Xb. Refer to pages 31-3325mmCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch & Sealant Cone-/120/120
Hilti25mm Dia. PE-Xa. Refer to pages 31-3225mmCP611a / CFS-IS Intumescent Sealant-/120/90
Hilti32mm Dia. PE-X/AL/PE. Refer to pages 31-3232mmCP611a / CFS-IS Intumescent Sealant-/120/60
Hilti32mm Dia. PE-X/AL/PE. Refer to pages 31-3332mmCP611a / CFS-IS Intumescent Sealant + 13mm Plasterboard Patch & Sealant Cone-/120/90
Hilti40mm ND uPVC Pipe. Refer to pages 28-3040mmuPVCCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant-/120/60
Hilti40mm ND uPVC Pipe. Refer to pages 28-3040mmuPVCCFS-C P 50/1.5" Fire Collar + CP606 Acrylic Sealant + 13mm Plasterboard Patch-/120/90
Hilti50mm ND uPVC Pipe. Refer to pages 28-3050mmuPVCCFS-C P 63/2.0" Fire Collar + CP606 Acrylic Sealant-/120/90
Hilti50mm ND uPVC Pipe. Refer to pages 28-3050mmuPVCCFS-C P 63/2.0" Fire Collar + CP606 Acrylic Sealant + 13mm Plasterboard Patch-/120/120
Hilti65mm ND uPVC Pipe. Refer to pages 28-3065mmuPVCCFS-C P 75/2.5" Fire Collar + CP606 Acrylic Sealant-/120/90
Hilti65mm ND uPVC Pipe. Refer to pages 28-3065mmuPVCCFS-C P 75/2.5" Fire Collar + CP606 Acrylic Sealant + 13mm Plasterboard Patch-/120/120
Hilti80mm ND uPVC Pipe. Refer to pages 28-3080mmuPVCCFS-C P 90/3" Fire Collar + CP606 Acrylic Sealant-/120/90
Hilti80mm ND uPVC Pipe. Refer to pages 28-3080mmuPVCCFS-C P 90/3" Fire Collar + CP606 Acrylic Sealant + 13mm Plasterboard Patch-/120/120
HiltiCable Bundle ≤ 36mm Dia. Any combination of Telecommunication cables, Cat5/6/7/8, Fiber Optic cables,RG6 Quad Shield Coax or TPS 2C+E up to 2.5mm2. Refer to pages 13-14Max. 36mmCableCP611a / CFS-IS Intumescent Sealant-/120/60
HiltiCable Bundle ≤ 36mm Dia. Any combination of Telecommunication cables, Cat5/6/7/8, Fiber Optic cables,RG6 Quad Shield Coax or TPS 2C+E up to 2.5mm2. Refer to pages 13-14Max. 36mmCableCP611a / CFS-IS Intumescent Sealant + CFS-P BA Putty Bandage-/120/90
HiltiCable Tray up to 600mm Wide with 9 x 400mm2 XLPE/PVC or PVC/PVC Sheath/Insulated Single Core Copper or Aluminum Power Cables. Refer to pages 21-27Cable2 x Layers CP670 Coated Board + CP611a / CFS-IS Intumescent Sealant + CFS-P BA Putty Bandage-/60/60
HiltiCable Tray up to 600mm Wide with AS1530.4 Standard D1 XLPE/PVC or PVC/PVC Sheath/Insulated Power Cables Cable Sets. Refer to pages 21-27Cable2 x Layers CP670 Coated Board + CP611a / CFS-IS Intumescent Sealant + CFS-P BA Putty Bandage-/120/90
HiltiCable Tray up to 600mm Wide with AS1530.4 Standard D2 Telecommunication Cable Sets. Refer to pages 21-27Cable2 x Layers CP670 Coated Board + CP611a / CFS-IS Intumescent Sealant + CFS-P BA Putty Bandage-/90/60
HiltiUp to 10 of Quad Shield Coax Cables. Refer to pages 13-14CableCP611a / CFS-IS Intumescent Sealant + CFS-P BA Putty Bandage-/120/90
HiltiUp to 16 of Telecommunication cables, Cat5/6/7/8 & Fiber Optic cables. Refer to pages 13-14CableCP611a / CFS-IS Intumescent Sealant-/120/90
HiltiUp to 16 of Telecommunication cables, Cat5/6/7/8 & Fiber Optic cables. Refer to pages 13-14CableCP611a / CFS-IS Intumescent Sealant + CFS-P BA Putty Bandage-/120/120
HiltiUp to 8 of TPS 2C+E up to 2.5mm2. Refer to pages 13-14CP611a / CFS-IS Intumescent Sealant-/120/60
HiltiUp to 8 of TPS 2C+E up to 2.5mm2. Refer to pages 13-14CP611a / CFS-IS Intumescent Sealant + CFS-P BA Putty Bandage-/120/90
Read more
Hobsonville Point

Hobsonville Point

CASE STUDY

Hobsonville Point: Enhancing Fire and Acoustic Protection with KOROK® Intertenancy Systems

Bringing Kiwi Ingenuity to Hobsonville Point Homes

Here at KOROK®, we’re stoked to have been part of the transformation of the old Hobsonville airbase into a new community. Our innovative KOROK KIR Intertenancy Residential Walls have been key in shaping around 3000 homes across this significant slice of land, including standout spots like the Te Uru Apartments, Walter Merton Road Terraces, Nugget Avenue Terraces, and Buckley A Precinct.

Hobsonville Point
Hobsonville Point

Being part of the Hobsonville Point development really showcases our ability for coming up with smart solutions that tackle the real-world challenges of modern building, especially when it comes to keeping fires at bay and cutting down on noise. Traditional wall setups in flats and hotels usually lean on linings to do this job. But our KIR walls change the game by ditching the need for these linings up top, making the whole building process simpler and slicker.

Smoother Sailing in Building and Design

Our walls have made it quicker and easier to get buildings up at Hobsonville Point. That’s good news for the teams on the ground and means residents can start enjoying their new digs sooner.

Keeping Costs Down

Thanks to the technology behind our KIR panels, we’ve cut down on waste, which means saving some dollars. Those savings can help make other parts of the development even better, making the whole neighbourhood a top spot to live.

Top-Notch Fire and Sound Safety

We’ve put our walls through the wringer to make sure they’re up to scratch for fire safety and noise control. That means folks living in Hobsonville Point can sleep easy, knowing they’ve got solid protection around them.

Built Solid for Extra Peace of Mind

The sturdy design of our walls means homes are not just safe but also built to last. That’s a big plus for anyone calling Hobsonville Point home, offering a secure spot for years to come.

Committed to Excellence in Innovation and Community Building

From the lively look of the Te Uru Apartments to the tidy and thoughtful design of the Walter Merton Road Terraces and the spot-on style of Buckley A Precinct, our KIR panels have been a foundation for success, delivering the goods on fire safety and quiet living.

As we look back on our role at Hobsonville Point, we’re chuffed to have delivered solutions that not only tick the boxes for what’s needed in today’s building scene but also help forge strong, safe, and green communities. Our dedication to coming up with better ways to do things will keep us at the forefront of making homes better for Kiwis everywhere.

Hobsonville Point

KOROK Systems used in this project

Intertenancy Terraced Housing Systems

Intertenancy Terraced Housing 

In terraced housing and town houses, conventional framed wall systems rely on the internal linings for fire-resistance. Penetrating these linings potentially destroys the fire-rated barrier.

Related Projects

Read more
Boathouse Bay

Cantilevers

Cantilevers

Designing cantilevered terraced houses is simplified with KOROK® fire and acoustic wall systems. Whether you need cantilevered eaves or cantilevered walls, KOROK has detailed solutions to suit your needs.

Our systems help you create functional and stylish designs, such as:

  • Weather protection with inset front doors for enhanced shelter.
  • Maximizing floor space with larger second-story extensions.

KOROK’s innovative cantilevered wall systems are engineered to provide superior performance, offering both structural stability and efficient installation for terraced house construction. Choose KOROK® to streamline your building process and meet the demands of modern architectural design.

Walter Merton Road Terraces: A New Standard in Terraced Housing

For Terraced Housing

Cantilevered terraced house design is easy with KOROK®. We have details for both cantilevered eaves and cantilevered walls. So if you’re wanting your buyers to be sheltered from the weather with an inset front door; or if you’re wanting to maximise your floor space with a larger second storey, we have the product to make that happen.

Cantilevered Eaves

Cantilevered Walls

For External Applications

A Typical Parapet Detail illustrates the structure and support of a parapet wall, commonly cantilevered from the main building structure. This detail focuses on connections that ensure stability and durability, including reinforcement and weatherproofing layers to protect against the elements. Cantilevered parapets require careful attention to load distribution and deflection control, as they extend outward without external bracing, creating a clean, streamlined edge on the building façade.

Typical parapet detail

Typical parapet detail

Read more
KOROK® 78mm Galv Panel

KOROK® 78mm Galv Panel

KOROK® 78mm Galv Panel

High Performing and Lightweight

KOROK® 78mm galv panels are rollformed from zinc coated steel strips. The steel from which the shells are manufactured conforms to AS/NZS1397:2001.

Steel shells have a base metal thickness of 0.4mm B.M.T. with a Z275 zinc coating. These panels have an aerated concrete core and weigh nominally 10.2kg per lineal metre.

Read more
KOROK® 51mm Galv Panel

KOROK® 51mm Galv Panel

KOROK® 51mm Galv Panel

High Performing and Lightweight

51mm KOROK® panels are rollformed from zinc coated steel strips. The steel from which the shells are manufactured conforms to AS/NZS1397:2001. Steel shells have a base metal thickness of 0.4mm B.M.T. with a Z275 zinc coating. These panels have an aerated concrete core and weigh nominally 10.2kg per lineal metre.

KOROK® produces 51mm panel. KOROK® 51mm panel provides a -/60/60 FRR and is perfectly suited for terraced house intertenancy walls and apartment intertenancy walls.  The narrower gauge allows you to keep more floor space as it isn’t taken up by walls.

KOROK® 51mm Galv Panel

Performance and Features

  • Fire Rating: KOROK® 51mm panels provide a fire resistance rating of -/60/60 FRR, meeting stringent safety requirements for intertenancy walls in terraced houses and apartments.
  • Acoustic Efficiency: Designed to reduce sound transmission, these panels ensure quieter living environments, making them an excellent choice for densely populated or high-traffic areas.
  • Space-Saving Design: The 51mm thickness allows for slimmer walls, helping to maximize valuable floor space without compromising structural integrity or performance.

 

KOROK® 51mm galv panels are used for:

Applications and Systems

  • Vertical Orientation: Panels are installed vertically and secured to timber or steel framing with aluminum brackets.
  • Versatility: Compatible with wall framing, insulation, and linings specified within the system appraisal, ensuring seamless integration into your building project.
  • Scope of Use: Appraised for all buildings of all importance levels as defined by AS/NZS 1170.

Projects using KOROK® 51mm Galv Panel

Read more
Intertenancy Apartment Systems Fire and Acoustic Rated Protection

Intertenancy Apartment Systems Fire and Acoustic Rated Protection

Fire and Acoustic Rated Protection for Intertenancy Apartment Systems

In multilevel buildings such as apartments and hotels, traditional framed wall systems often depend on wall linings to achieve fire resistance and effective acoustic control. However, KOROK® has designed an innovative solution: KIR KOROK® Intertenancy Residential Walls. These advanced wall systems eliminate the need for linings in the ceiling plenum while maintaining exceptional fire resistance and acoustic performance.

This breakthrough simplifies the design, detailing, and construction of intertenancy apartment walls, leading to quicker construction times, less material waste, and significant cost savings.

Key Benefits of KOROK® Intertenancy Apartment Walls:

  • Proven fire-rated protection and acoustic insulation for multilevel buildings.
  • Solid wall construction for enhanced security and long-term durability.
  • Faster installation process, reducing overall project timelines.
  • Eco-friendly solution with waste reduction..

Explore our CAD Library to access detailed DWG files for multilevel intertenancy systems. Download the full KOROK Intertenancy Multilevel Systems Literature to learn more about our fire and acoustic rated protection.

Download Literature

KOROK Intertenancy Multilevel Systems

Link to System SpecPanelsSTCSTC RatingFRRFire RatingOverall System ThicknessLiningFrameCavityFlashingDensityApplicationView CAD Files in LibraryMasterSpec Work Section
EX1




78mm3636-40 -/120/120120n/ano linings n/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX278mm4241-54 -/180/180180n/a1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternativesn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX378mm3636-40 -/120/120120n/aLongrun profiled steel cladding system as selectedn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX478mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives.
Longrun profiled steel cladding system as selected.
n/an/a400 kg/m3External

4259KE - Korok Exterior Wall Systems
EX578mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives. Longrun profiled steel cladding system as selectedn/an/a400 kg/m3External
4259KE - Korok Exterior Wall Systems
FS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS278mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track.400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS378mm4036-40 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS478mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
KIM0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one side28mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard each side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0851mm6160-64 -/60/6030-60181mm1 layer 13mm to GIB® Noiseline or equivalent each side64mm steel frame one side16mm Furring channel on 237 clips direct fix the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0951mm6060-64 -/60/6030-60175mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1251mm6160-64 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side64mm steel frame one side16mm Furring channel directly fixed the other. Minimum 10mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1351mm6460-64 -/60/6030-60194mm1 layer 13mm GIB® Noiseline or equivalent one side +2 layers 13mm GIB® Noiseline or equivalent the other64mm steel frame one side16mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one side, 28mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel
5171KI - Korok Inter-tenancy Wall Systems
KIR0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0851mm6160-64 -/60/6030-60181mm1 layer 13mm GIB® Noiseline or equivalent each side
64mm steel frame one side, 16mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0951mm6060-64 -/60/6030-60177mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1451mm5555-59 -/60/6030-60109mm1 layer 13mm GIB® Noiseline plasterboard or equivalent one side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1578mm5655-59 -/120/120120141mm1 layer 13mm GIB Noiseline® or equivalent one side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1678mm5755-59 -/120/120120154mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1778mm6160-64 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1878mm5855-59 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1978mm5555-59 -/120/120120204mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2078mm6060-64 -/120/120120233mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent the other side
64mm steel frame one side, 28mm Furring channel on BETAGRIP® Clips the other sideMinimum 15mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2178mm6965-and above -/120/120120262mm1 layer 13mm GIB Noiseline® or equivalent each side
64mm steel frame each sideMinimum 108mm between the framing. Framing not to touch KOROK® panel400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIT01A51mm6460-6460/60/3030-60288mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0151mm6360-6460/60/6030-60288mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT01 Modified51mm6360-6460/60/6030-60282mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0251mm6665-and above60/60/6030-60288mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0351mm6765-and above60/60/6030-60288mm1 layer 10mm GIB Noiseline® each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0451mm6965-and above60/60/6030-60294mm1 layer 13mm GIB Noiseline® each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0551mm6665-and above60/60/6030-60294mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT06A78mm6360-64120/120/6030-60315mm1 layer 10mm GIB® Standard each side 90mm90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0678mm6360-64120/120/120120315mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0778mm6665-and above120/120/120120315mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0878mm6765-and above120/120/120120315mm1 layer 10mm GIB Noiseline® one side, 1 layer 10mm GIB Aqualine (wet) or 10mm GIB Noiseline® (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0978mm6965-and above120/120/6030-60321mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB Aqualine (wet) or 13mm Noiseline (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT1078mm6665-and above120/120/120120321mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KLSD6
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD7
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD8
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® direct-fixed one side OR 2 layers 10mm GIB Fyreline® direct-fix one side n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD9
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KWR1
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR2
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3A
78mm4241-54 -/180/18018098mm2 layers 10mm GIB Fyreline® direct-fixed one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3B
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3
78mm4241-54 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR4
78mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR5
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR6
78mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
NCS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Noise control<img decoding="async" src="https://www.korok.com/wp-content/uploads/2024/06/FS1-vertical-150x150.png" alt="" width="150" height="150" 5216KC - Korok® Commercial Interior Wall Systems
NCS278mm5855-59 -/120/120120175mm1 layer of 13mm GIB Noiseline® + R1.8 insulation64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS378mm5955-59 -/120/120120188mm1 layer of 13mm GIB Noiseline® on one side with R1.8 insulation, 1 layer of 13mm GIB® Standard on the other side64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS478mm x27665-and above -/120/120120600mm1 layer 90mm x 42kg/m3 insulation attached to one internal facen/a444mm between KOROK® panels600 kg/m3Cinema

5216KC - Korok® Commercial Interior Wall Systems
K5151mm3636-40 -/60/6030-6051mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track
OR
13 mm GIB Fyreline® or acceptable GIB® alternatives x 120 mm strip with
sealant is fixed at 250 mm centres top and bottom, using 6g x 32 mm
drywall screws.
600 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
See Scissor Stair information hereScissor stairs
See Passive Fire / Penetrations information here Passive fire / penetrations
See Connections to Steel information here Connections to steel
Read more
System Selector

System Selector

device top

KOROK® SYSTEM SELECTOR

Choose the right system for your next project

device bottom

Find, Compare & Download the best KOROK System

  • Use filters to refine your search.
  • Use the ‘CTRL’ key for multiple selections.
Link to System SpecPanelsSTCSTC RatingFRRFire RatingOverall System ThicknessLiningFrameCavityFlashingDensityApplicationView CAD Files in LibraryMasterSpec Work Section
EX1




78mm3636-40 -/120/120120n/ano linings n/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX278mm4241-54 -/180/180180n/a1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternativesn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX378mm3636-40 -/120/120120n/aLongrun profiled steel cladding system as selectedn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX478mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives.
Longrun profiled steel cladding system as selected.
n/an/a400 kg/m3External

4259KE - Korok Exterior Wall Systems
EX578mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives. Longrun profiled steel cladding system as selectedn/an/a400 kg/m3External
4259KE - Korok Exterior Wall Systems
FS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS278mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track.400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS378mm4036-40 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS478mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
KIM0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one side28mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard each side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0851mm6160-64 -/60/6030-60181mm1 layer 13mm to GIB® Noiseline or equivalent each side64mm steel frame one side16mm Furring channel on 237 clips direct fix the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0951mm6060-64 -/60/6030-60175mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1251mm6160-64 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side64mm steel frame one side16mm Furring channel directly fixed the other. Minimum 10mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1351mm6460-64 -/60/6030-60194mm1 layer 13mm GIB® Noiseline or equivalent one side +2 layers 13mm GIB® Noiseline or equivalent the other64mm steel frame one side16mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one side, 28mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel
5171KI - Korok Inter-tenancy Wall Systems
KIR0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0851mm6160-64 -/60/6030-60181mm1 layer 13mm GIB® Noiseline or equivalent each side
64mm steel frame one side, 16mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0951mm6060-64 -/60/6030-60177mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1451mm5555-59 -/60/6030-60109mm1 layer 13mm GIB® Noiseline plasterboard or equivalent one side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1578mm5655-59 -/120/120120141mm1 layer 13mm GIB Noiseline® or equivalent one side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1678mm5755-59 -/120/120120154mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1778mm6160-64 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1878mm5855-59 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1978mm5555-59 -/120/120120204mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2078mm6060-64 -/120/120120233mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent the other side
64mm steel frame one side, 28mm Furring channel on BETAGRIP® Clips the other sideMinimum 15mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2178mm6965-and above -/120/120120262mm1 layer 13mm GIB Noiseline® or equivalent each side
64mm steel frame each sideMinimum 108mm between the framing. Framing not to touch KOROK® panel400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIT01A51mm6460-6460/60/3030-60288mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0151mm6360-6460/60/6030-60288mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT01 Modified51mm6360-6460/60/6030-60282mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0251mm6665-and above60/60/6030-60288mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0351mm6765-and above60/60/6030-60288mm1 layer 10mm GIB Noiseline® each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0451mm6965-and above60/60/6030-60294mm1 layer 13mm GIB Noiseline® each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0551mm6665-and above60/60/6030-60294mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT06A78mm6360-64120/120/6030-60315mm1 layer 10mm GIB® Standard each side 90mm90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0678mm6360-64120/120/120120315mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0778mm6665-and above120/120/120120315mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0878mm6765-and above120/120/120120315mm1 layer 10mm GIB Noiseline® one side, 1 layer 10mm GIB Aqualine (wet) or 10mm GIB Noiseline® (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0978mm6965-and above120/120/6030-60321mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB Aqualine (wet) or 13mm Noiseline (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT1078mm6665-and above120/120/120120321mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KLSD6
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD7
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD8
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® direct-fixed one side OR 2 layers 10mm GIB Fyreline® direct-fix one side n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD9
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KWR1
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR2
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3A
78mm4241-54 -/180/18018098mm2 layers 10mm GIB Fyreline® direct-fixed one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3B
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3
78mm4241-54 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR4
78mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR5
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR6
78mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
NCS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Noise control<img decoding="async" src="https://www.korok.com/wp-content/uploads/2024/06/FS1-vertical-150x150.png" alt="" width="150" height="150" 5216KC - Korok® Commercial Interior Wall Systems
NCS278mm5855-59 -/120/120120175mm1 layer of 13mm GIB Noiseline® + R1.8 insulation64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS378mm5955-59 -/120/120120188mm1 layer of 13mm GIB Noiseline® on one side with R1.8 insulation, 1 layer of 13mm GIB® Standard on the other side64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS478mm x27665-and above -/120/120120600mm1 layer 90mm x 42kg/m3 insulation attached to one internal facen/a444mm between KOROK® panels600 kg/m3Cinema

5216KC - Korok® Commercial Interior Wall Systems
K5151mm3636-40 -/60/6030-6051mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track
OR
13 mm GIB Fyreline® or acceptable GIB® alternatives x 120 mm strip with
sealant is fixed at 250 mm centres top and bottom, using 6g x 32 mm
drywall screws.
600 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
See Scissor Stair information hereScissor stairs
See Passive Fire / Penetrations information here Passive fire / penetrations
See Connections to Steel information here Connections to steel
Read more